Product Descriptions: 

    The AE8600D is a high-precision diffraction-grating, high-resolution optical spectrometer with wavelength range of 600nm to 1700nm. The 10.1” LCD touchscreen and concise graphical user interface of AE8600D offer the easiest way to handle optical spectrum analysis.

AE8600D provides a wide selection of test methodology, including laser spectrum scans (DPB, FP), WDM system testing, EDFA system testing, transmittance and drift testing, which are essential for in-field and factory applications. The AE8600D offers exceptional stability and reliability, high-speed spectral sweeping, and multiple ways to export and analyze measurement data.  It’s the ideal instrument for fast and precise optical spectral testing to satisfy long-term investment with the best cost performance value.


Key Benefits: 

     •Single mode and multi-mode wavelength range from 600nm to 1700nm.

     •Wide range of power measurement from +20dBm to -90dBm and wide dynamic range up to 75dB typical

     •Outstanding wavelength & power measurement accuracy with λ resolution up to 0.02nm and built-in calibration source(Option)

     •WDM, Laser, and EDFA test modes

     •10.1" 1280x800 TFT touchscreen LCD

     •Multiple data storage and interface – LAN (RJ-45), USB, RS232, GP-IB(Option) … etc.

     •Customizable auto-test scenario

Typical Applications: 


Optical Amplifier (EDFA) Measurement

• PSSE– Source Spontaneous Emission (SSE) spectral density at the signal wavelength

• PASE – Total noise spectral density, including SSE, at the signal wavelength

• Gain

• Noise coefficient

 

Distributed Feedback Laser Diode (DFB LD) Analysis

• Center wavelength and power

• Total power

• Bandwidth

• Side Mode Suppression Ratio (SMSR)

• Optical Signal-to-Noise Ratio (OSNR)

• Drifting of center wavelength

 

Wavelength-Division Multiplexing (WDM) Channel Analysis

• Channel wavelength and power

• Channel drifting

• Optical Signal-to-Noise Ratio (OSNR)

• Bandwidth

Fabry-Perot Laser Diode (FP LD) Analysis

• Center wavelength and power

• Root-Mean-Square (RMS) and Full Width at Half Maximum (FWHM) of power spectral density over wavelength range

• Bandwidth

• Mode separation


Gas measurement

When used with broadband light sources such as super continuum (SC) or super luminescent diode (SLD), the AE8600D can display the light absorption spectrum of the measured gas mixture.


Notch Width Measurement

With notch width measurement, it is possible to measure pass band width/notch width from the measure waveform of a filter with V-character type or U-character type wavelength characteristics.


Functions: 

Item

Function

Measurement

Sweep mode

Repeat sweep, single sweep, AUTO (automatically sets measuring condition) , sweep between marker, data logging

 

Condition Setting

Center wavelength, span, wavelength sampling points, wavelength resolution, measurement sensitivity, high dynamic mode, average count(1 to 999), double-speed measurement mode, smoothing, APC level correction

Others

Sweep status output, analog output

Display

Vertical scale

Level scale (0.1 to 10dB/div., linear) , level subscale (0.1 to 10dB/div., linear) , reference level display, DIV display (8, 10 or 12) , power density (dB/nm), dB/km, %, noise mask

Horizontal scale

wavelength (nm), frequency(THz), zoom

Display mode & items

Single waveform display, split screen display, data table display, label display, template display, measurement condition display

Trace

 

Trace functions

Simultaneous display of 7 independent traces, max/min value detection display, calculation between traces display, normalized display, curve fit display, peak curve fit display, marker curve fit display, roll averaging (2 to 100 times)

Others

Trace copy /trace clear, Write/Fix setting, show / hide setting

Marker &Search

Marker

Delta marker(Max.1024), vertical / horizontal line markers, advanced marker

Search

Peak search, bottom search, auto search (On/OFF), search between vertical axis line marker, search within zoom area

Data analysis

 

Analysis functions

Spectral width analysis (threshold, envelope, RMS, peak-RMS, notch) , WDM (OSNR) analysis, EDFA-NF analysis, filter peak/bottom analysis, WDM filter peak/bottom analysis, DFB-LD/FP-LD/LED analysis, SMSR analysis, power analysis, PMD analysis

Others

Auto analysis execution setting(ON/OFF), analysis between vertical axis line markers, analysis within the zoom area

Other functions

Alignment

Auto alignment using built-in calibration light source.


Specifications: 

Optical Spectrum Measurement :

Applicable fiber

SM(9.5/125μm), MMF(50/125μm, 62.5/125μm)

Wavelength range1

600 ~ 1700nm

Wavelength resolution bandwidth

0.02 ~ 2nm

Wavelength resolution setting1,2

0.02nm, 0.05nm, 0.1nm, 0.2nm, 0.5nm, 1nm, 2nm

Wavelength resolution bandwidth accuracy1,2,5

±5%(1450 to 1620nm, Resolution setting:≧0.1nm, after performing the Resolution Calibration function, at the wavelength of resolution calibration)

 

Wavelength accuracy1,2,5

1520 to 1620 nm ±0.015 nm

1450 to 1520 nm ±0.025 nm entire wavelength range ±0.1 nm

Wavelength repeatability1,2

±0.01 nm (1 min.)

Wavelength linearity1,2,5

±0.015 nm (1520 to 1580 nm)

±0.025 nm (1450 to 1520 nm,1580 to 1620 nm)

Min. sampling resolution1

0.001nm

 Optical Power Measurement :

 

Level sensitivity2,3,4,7

-90dBm(1300-1620nm,resolution ≥0.05nm,sensitivity:HIGH3)

-85dbm(1000-1300nm,resolution ≥0.05nm,sensitivity:HIGH3)

-55dBm(600-1000nm,resolution ≥0.05nm,sensitivity:HIGH3)

Maximum input power2,3

+20dBm(Per channel,full range)

Maximum safe input power2,3

±25dBm(Total input power)

Level accuracy2,3,4,6

±0.3dB(1310/1550nm, input level: -20dBm)

Level linearity2,3

±0.08dB(input level:-50~+10dBm, sensitivity: HIGH1/HIGH2/HIGH3)

Level flatness2,3,6

±0.1dB(1520 to 1580nm), ±0.2dB(1450 to 1520nm, 1580 to 1620nm)

Wavelength sampling points

101 to 50001, AUTO

Optical return loss11

>35dB (with angled-PC connector)

Polarization dependence2,3,6

±0.08dB(1550nm)

 

Dynamic range1,2,8

Peak ±0.1nm 50dB(resolution: 0.02nm) Peak ±0.4nm 70dB(resolution: 0.05nm) Peak ±1.0nm  75dB(resolution: 0.05nm)

Level sensitivity setting

NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2, HIGH3

Stray-light suppression ratio7,10

75dB

Sweep time1,7,9

0.2s(NORM_AUTO),0.8s(NORMAL),1.8s(MID)

4s(H1),16s(H2),60s(H3) SPAN ≤100nm Sampling Points 1001

Warm-up time

Minimum 1hour


General Specifications:

Display

10.1 inch TFT LCD touchscreen (Resolution: 1280×800)

 

Interface

USB2.0 ×5, USB 3.0, VGA, GP-IB (Option)

RJ45 LAN port (10M/100M/1000M), RS232-DB9

Data storage

Internal storage: 120GB hard-drive File types: CSV,Binary,BMP

Operating temperature

+5 ~ +35℃

Storage temperature

-10 ~ +50℃

Power supply

AC  100-240V 1.7A 50~60Hz

Dimensions

427*221*448 (mm)

Weight

17kg

Performance  temperature

+18 ~ +28℃

Safety standards

EN61010-1

EMC(Emission)

EN IEC 61326-1, EN IEC 61326-2-1 and CISPR 16-1 series standards, Class A Group 1, IEC61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8, IEC 61000-4-4, IEC61000-4-6, IEC 61000-4-11


Remarks:

1. Horizontal axis scale: In wavelength display mode.

2. 9.5/125 μm single mode fiber (PC polishing), after warm-up of 1 hours, after alignment with a built-in wavelength reference

light source or single longitudinal mode laser (wavelength: 1520 to 1560 nm, wavelength stability: ±0.01 nm or less)

3. Vertical scale: absolute value level display mode, resolution setting: 0.05 nm or more, resolution correction: OFF

4. When using 9.5/125 μm single mode fiber

5. After wavelength calibration using a built-in wavelength reference light source or single longitudinal mode laser

6. With the resolution setting of 0.05 nm, at ambient temperature of 23 ±3 °C.

7. High dynamic mode: OFF, pulse light measurement mode: OFF, resolution correction: OFF

8. 1523 nm, high dynamic mode:SWITCH, resolution correction: OFF

9. Span 100 nm or less, wavelength sampling points: 1001, averaging times: 1

10. When applying a HeNe laser (1523 nm), resolution: 0.1 nm, 1520 nm to 1620 nm (excluding peak wavelength ± 2 nm).

11. When using the signal mode fiber with our standard Angled PC connector, it is 15 dB(Typ.) when using the PC connector

Ordering Information: 

Description                                                   Part No.                            Ordering No.

AE8600D Optical Spectrum Analyzer

(standard package)

AE8600D

0260.8600.07

FC Connector Adapter for Optical Input(standard configuration installed at factory)

AE8600-001

6260.0400.03

CD with User Manual

AE8600-003

6260.0600.09

Calibration and Compliance Certificate

DS1001-001

6190.0600.05

Options

SC Connector Adapter for Optical Input

AE8600-002

6260.0400.04

Built-in Calibraton Light Source(default with FC/APC Connector Adapter)

AE8600-200

2260.8600.00

PCIE-GPIB

AE8600-700

6260.0400.05

Calibration Certificate (with data)

AE8600-004

6260.0600.10

Power Cord (1.5m)

SA8300-700

6190.0500.40

Power Adaptor Plug Cord (Europe)

AE4000-733

6290.0500.03

Power Adaptor Plug Cord (Unite States)

AE4000-734

6290.0500.04

Power Adaptor Plug Cord (United Kingdom)

AE4000-735

6290.0500.05

Power Adaptor Plug Cord (Australia)

AE4000-736

6290.0500.06